TY - UNPB Y1 - 2015/06/04/ T2 - ISMRM 23st Annual Meeting A1 - Oksuz, Ilkay A1 - Mukhopadhyay, Anirban A1 - Bevilacqua, Marco A1 - Yang, Hsin-Jung A1 - Dharmakumar, Rohan A1 - Tsaftaris, Sotirios A. AV - none TI - Effect of BOLD Contrast on Myocardial Registration ID - eprints2768 M2 - Toronto, Ontario, Canada UR - http://eprints.imtlucca.it/2768/ N2 - Cardiac phase-resolved Blood-Oxygen-Level-Dependent (CP-BOLD) MRI is a new approach for detecting ischemia at rest. Currently disease assessment relies on segmental analysis and uses only a few images in the phase-resolved acquisition. It is expected that using all phases can permit pixel-level characterization of CP-BOLD MRI. In this study, state-of-the-art image registration techniques are evaluated on cardiac BOLD MRI data for the first time. The results show that cardiac phase-dependent variations in myocardial BOLD contrast in CP-BOLD images creates a statistically significant decrease in the accuracy compared to standard Cine MR images acquired under conditions of health and myocardial ischemia. ER -